AccessShieldHubAccess control, CCTV, alarms, turnstiles, smart locks, and perimeter security equipment for global industrial buyers.
2/4 Wire Conventional Fire Alarm Control Panel for Fire Alarm System 16 Zones - Fire Alarm and Fire
Alarm Panels

2/4 Wire Conventional Fire Alarm Control Panel fo | RFQ Sourcing Details

Alarm Panels · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryAlarm Panels
Unitset
Size48.00cm * 42.00cm * 18.50cm Package Gross Weight 10.000kg Lead Time 15 days-50 Pieces) To be negotiated
TypeConventional Zone Number 4 Zone, 8 Zone, 16 Zone Optional Net
ColorRed Fire Panel
UsageFire
OriginChina
Weight7.8kg
CategoryAlarm Panels
AvailabilityInquiry required
Source date2026-06-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Alarm Panels. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Cheap 2/3/4 Wire Conventional Fire Alarm Control Panel for fire alarm system Fire alarm control panel SR-P01-4 4 zones conventional fire alarm control panel SR-P01-8 8 zones conventional fire alarm control panel SR-P01-16 16 zones conventional fire alarm control panel The SR-P01 Series Conventional Fire Alarm Control Panel is a 24 volt, four to sixteen-zone, Class B, Conventional Fire Alarm Control Panel.

Designed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective SR-P01 Series can be used in a variety of low- to mid-sized applications.

Main Features: Four, Eight, Sixteen Zone Style B (Class B) Initiating Device Circuits (IDCs), All zones accept two-wire smoke detectors and any normally-open . Two Supervisory Input with DC12V output, ideal to connect security alarm devices. Three General Alarm, Trouble and Supervisory, Form A Relay Output.

One, Two, Four Built-in Sound Output, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs), NACs may be programmed: Silenceable or Non-Silenceable. 3.0 amps of total system power. Resettable DC24V & Non-resettable DC24V Output. Zone Input Short Circuit can be set to "Alarm" or " Fault" mode.

RS485 Communication Port (optional). Automatic/Manual mode can be programmed. Disable/Enable control per Zone (IDC) can be programmed. Disable/Enable Sound Output(NACs) can be programmed. Technical specification: AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only.

Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps.

Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output.

Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive) Product Pictures : Model NO: SR-P01-16 Usage Fire Certification CE Alarm Volume (within 1m) ≥80dB Networking Mode Wire Wiring Mode Sub-Line System Color Red Fire Panel Type Conventional Zone Number 4 Zone, 8 Zone, 16 Zone Optional Net Weight 7.8kg;Size: 48.00cm * 42.00cm * 18.50cm Package Gross Weight 10.000kg Lead Time 15 days (1 - 50 Pieces) To be negotiated ( > 50 Pieces);Transport Carton;Specification: 220VAC, 50 Hz.;Trademark: SUMRING;Origin: China;HS Code: .

Wire | Applications and Buyer Notes

Wire is organized as a sourcing-ready Alarm Panels reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions befor

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Alarm PanelsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Size
48.00cm * 42.00cm * 18.50cm Package Gross Weight 10.000kg Lead Time 15 days-50 PBased on visible page data; confirm exact value in the RFQ.
Type
Conventional Zone Number 4 Zone, 8 Zone, 16 Zone Optional NetBased on visible page data; confirm exact value in the RFQ.
Color
Red Fire PanelBased on visible page data; confirm exact value in the RFQ.
Usage
FireBased on visible page data; confirm exact value in the RFQ.
Origin
ChinaBased on visible page data; confirm exact value in the RFQ.
Weight
7.8kgBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryAlarm Panels
Unitset
Size48.00cm * 42.00cm * 18.50cm Package Gross Weight 10.000kg Lead Time 15 days-50 Pieces) To be negotiated
TypeConventional Zone Number 4 Zone, 8 Zone, 16 Zone Optional Net
ColorRed Fire Panel
UsageFire
OriginChina
Weight7.8kg
capacity18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system
TrademarkSUMRING
CertificationCE Alarm Volume-Line System
Specification220VAC, 50 Hz.
specificationsModel NO: SR-P01-16
Transport PackageCarton
Package Gross Weight10.000kg Lead Time 15 days-50 Pieces) To be negotiated

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

AccessShieldHub related sourcing paths

Related categories AccessShieldHub related paths

Alarms and Perimeter Security

Access Control Systems

CCTV and Video Surveillance

Related applications AccessShieldHub related paths

Commercial Building Security

Factory Access Control

AccessShieldHub procurement phrases

AccessShieldHub related product samples

Supplier profile

AccessShieldHub Imported Supplier Pool
主营:Alarm Panels

View full profile >